Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Korean Neurosurgical Society ; : 568-673, 2018.
Article in English | WPRIM | ID: wpr-788722

ABSTRACT

OBJECTIVE: Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons.METHODS: We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1–6) with classical position (anesthesiologist and monitor were placed near to patient’s head. Surgeons were standing classically near to patient’s body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient’s belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1–2 mm penetration, 2–4 mm penetration and >4 mm penetration.RESULTS: Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003).CONCLUSION: Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon’s position standing near to patient’s head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.


Subject(s)
Humans , Anesthesia , Deception , Head , Pedicle Screws , Posture , Retrospective Studies , Spine , Surgeons , Thoracic Vertebrae
2.
Journal of Korean Neurosurgical Society ; : 568-673, 2018.
Article in English | WPRIM | ID: wpr-765292

ABSTRACT

OBJECTIVE: Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons. METHODS: We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1–6) with classical position (anesthesiologist and monitor were placed near to patient’s head. Surgeons were standing classically near to patient’s body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient’s belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1–2 mm penetration, 2–4 mm penetration and >4 mm penetration. RESULTS: Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003). CONCLUSION: Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon’s position standing near to patient’s head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.


Subject(s)
Humans , Anesthesia , Deception , Head , Pedicle Screws , Posture , Retrospective Studies , Spine , Surgeons , Thoracic Vertebrae
3.
Journal of Korean Neurosurgical Society ; : 410-413, 2016.
Article in English | WPRIM | ID: wpr-45405

ABSTRACT

Lumbar radiculopathy is generally caused by such well-recognized entity as lumbar disc herniation in neurosurgical practice; however rare pathologies such as thrombosed epidural varix may mimic them by causing radicular symptoms. In this case report, we present a 26-year-old man with the complaint of back and right leg pain who was operated for right L4-5 disc herniation. The lesion interpreted as an extruded disc herniation preoperatively was found to be a thrombosed epidural varix compressing the nerve root preoperatively. The nerve root was decompressed by shrinking the lesion with bipolar thermocoagulation and excision. The patient's complaints disappeared in the postoperative period. Thrombosed lumbar epidural varices may mimic lumbar disc herniations both radiologically and clinically. Therefore, must be kept in mind in the differential diagnosis of lumbar disc herniations. Microsurgical techniques are mandatory for the treatment of these pathologies and decompression with thermocoagulation and excision is an efficient method.


Subject(s)
Adult , Humans , Decompression , Diagnosis, Differential , Electrocoagulation , Leg , Methods , Pathology , Postoperative Period , Radiculopathy , Varicose Veins
SELECTION OF CITATIONS
SEARCH DETAIL